Assessment by calculation of aluminium and steel scaffold beams in accordance with BS EN 1999. Physical testing to service and ultimate limit states, and to destruction, for validation of the derived safe working loads. Free weight and hydraulic loading is adopted as necessary to replicate in service loading conditions.